One sample provides rapid and accurate fructosamine levels to help you manage and diagnose diabetic dogs and cats. Close the sample drawer and press the Start button on the analyser. Footer navigation. Step-by-step instructions make it easy. xChekPlus Resources No Color or Poor Color Development . Catalyst One Chemistry Analyser Certificate Course Safety materials. Accurately measure one part undiluted urine (e.g., 100 µL) and transfer it to a Catalyst* sample cup. Learn how to run Quality Control (QC) on the IDEXX Catalyst Dx Chemistry Analyzer. Catalyst SDMA White Paper. When the analyzer experiences a problem, an alert message appears on the upper right side of the IDEXX VetLab Station title bar, the LED on the front panel of the Catalyst One analyzer flashes red, and the Catalyst One icon on the IDEXX VetLab Station Home screen appears with an Alert status. UCRE and UPRO are included with the Catalyst Urine P:C Ratio. Operator's Guide. Running progesterone on a Catalyst One Chemistry Analyser. One sample, one run, and the answers you need to act early to improve patients’ lives. Load the slide, sample, and reagent. Catalyst One Chemistry Analyser Unprecedented clinical insight in one sample run during the patient visit In one run with one sample, get chemistry and electrolyte results in only 8 minutes, total T 4 in as little as 15 minutes. Always on, proactively monitoring and adjusting IDEXX analyzers remotely; Aggregates data to improve performance and drive quality improvements ; Shares data to a central dashboard to facilitate customer support Learn more. Do you need more assistance? The Instruments screen displays. Screen at-risk animals to detect clotting problems during a wellness examination or prior to surgery and avoid bleeding complications during or afterwards. Using only 25.4 centimeters of linear countertop, Catalyst One is the perfect fit for clinics of any size. The service proactively assesses your analyzer's performance and provides remote adjustments that resolve issues before problems arise. See our Privacy Policy. Total T 4 Testing Guide. Reference laboratory accuracy and comparable reportable range for results in just 15 minutes per run. Livestock and Poultry Diagnostics. IDEXX considers proper processing of personal data to be highly important. Results available during the veterinary patient visit for improved pet owner understanding and compliance. Load the slide, sample, and reagent. manuals, quick reference guides, sample preparation posters, In one run with one sample, get chemistry and electrolyte results in only 8 minutes, total T. Results available during the veterinary patient visit for improved pet owner understanding and compliance. • If the Ethernet icon is red, the analyzer has lost connection to the router. Two tests in one run help you detect and quantify proteinuria and diagnose early renal disease. To resolve the issue, reboot the analyzer. Cl, K, and Na are part of the Catalyst Lyte 4 CLIP. IDEXX SNAP tests are very reliable. How to run Catalyst Bile Acids Running bile acids on a Catalyst One Chemistry Analyser. Catalyst Progesterone Quick Reference Guide IMPORTANT: You must initiate the QC workflow through your IDEXX VetLab Station (not a practice management system) in order for the reference ranges to print. Get a more complete picture of your patient’s health with IDEXX VetConnect PLUS. User Guide. Establish a baseline and monitor NSAID therapy. analyzers to the IDEXX VetLab Station helps you attain a comprehensive picture of your patient’s health, with the ability to view test results from multiple analyzers on a single report, determine disease progression with parameter-trending capabilities, and more. To learn more about cookies and how we use them, and to learn how to change your cookie settings, please visit our Cookie Statement. SNAP Test Troubleshooting. Comparable range to IDEXX Reference Laboratories (1.0-180.0 µmol/L). Run Catalyst Progesterone to inform successful breeding management. Test may not have been prespotted. IDEXX SmartService Solutions. Contact your Abaxis Representative for more info. Using the Catalyst Total T 4 Test. Discard the control vial after one day. Use this panel for comprehensive equine testing. Running UPC on your catalyst one. Do you need more assistance? Sample Type Sample Volume Required Whole blood 0.7 cc (700 µL) Fill to the lowest line on the separator Serum, plasma, or urine Varies depending on the number of slides being run. Sitemap. Run individually or easily add electrolytes to any chemistry panel. operator to any problems. 3. The addition of AST makes it ideal for identifying liver damage. Combine with a CBC, electrolytes and tests such as total T4, when indicated. Order now. Download the quick reference guide Running progesterone on a Catalyst Dx Chemistry Analyser Enter the sample information on the IDEXX VetLab Station. Catalyst Dx Chemistry Analyser Manage more cases simply and efficiently Load and go: run multiple samples for results in minutes. Close the sample … Note: Tests noted in bold font are only available in panel format. IDEXX Learning Center (U.S.) Catalyst One Chemistry Analyzer Course. When the analyzer experiences a problem, an alert message appears on the upper right side of the IDEXX VetLab Station title bar, the LED on the front panel of the Catalyst One analyzer flashes red, and the Catalyst One icon on the IDEXX VetLab Station Home screen appears with an Alert status. Page 12: Catalyst One Analyzer Consumables Tap the Catalyst Dx tab. IDEXX Vetlab Station can be further connected to the Provet Cloud with bi … A comprehensive chemistry profile with GGT, valuable for assessing liver function, particularly in feline patients. Progesterone test results are available approximately 12 minutes after the start of the run. 1. SDMA Test Algorithm. However, if you have problems with a SNAP test, read the information below for help, and then rerun the test. Total T 4 (TT 4) Easily screen, diagnose and manage thyroid disease during the patient visit. Accurately measure one part diluent (use the same volume as used for urine in step 1) and add it to the sample cup used in step 1. By using this website you agree to our use of these cookies. Visit https://www.idexx.co.uk/en-gb/veterinary/support/documents-resources/catalyst-dx-resources/ A comprehensive chemistry profile with amylase and lipase, making it ideal for canine patients. Total T 4 Testing Guide. Learn more about ordering directly from IDEXX and order your in-house tests and supplies today. Catalyst CRP White Paper. Troubleshooting Catalyst analyzer *Refer to the Catalyst Operator’s Manual for troubleshooting information. Total T 4 can be added to any test panel, allowing for a comprehensive chemistry, electrolyte and total T 4 profile in one run with a single patient sample in approximately 15 minutes.. Tap the quality control lot number you are using and tap Run QC. Results available during the veterinary patient … It allows you to connect to one or more IDEXX analysers, such as LaserCyte, ProCyte Dx, Catalyst Dx and LaserCyte Dx. Tap Instruments on the IDEXX VetLab Station Home screen. Catalyst One; IDEXX VetLab Station; SediVue Dx; ProCyte Dx; SNAP Pro; All analysers; Software & services Software & services ... Catalyst One Chemistry Analyser Manuals and Resources. Enter the sample information on the IDEXX VetLab Station. Test may not have been prespotted. Up to 73% of veterinary samples are compromised.1 See how dry-slide technology ensures accurate results even from compromised samples. 3. Expanding menu of 34 tests includes advanced diagnostics, like fructosamine, phenobarbital, urine P:C ratio, SDMA, and progesterone. Running Dilutions on your Catalyst One Analyzer. Catalyst One* Catalyst Dx* Load reagent here Load TT4 slide here IDEXX Technical Support U.S./Canada 1-800-248-2483 Europe 00800 1234 3399 Frequently asked questions Question Answer Is the Catalyst* Total T4 Test just a slide? IDEXX (Material) Safety Data Sheets ([M]SDS) You can troubleshoot this issue by looking at the icons on the analyzer: • If the lost connection icon appears, the analyzer has lost connection to the IDEXX VetLab* Station. IDEXX - How to reseat the lockbar on Catalyst One - YouTube Add the Catalyst SDMA Test to any CLIP and get complete results during the patient visit. When the analyzer experiences a problem, an alert message appears on the upper right side of the IDEXX VetLab Station title bar, the LED on the front panel of the Catalyst One analyzer flashes red, and the Catalyst One icon on the IDEXX VetLab Station Home screen appears with an Alert status. IDEXX (Material) Safety Data Sheets ([M]SDS) Sitemap. 2. IDEXX Vetlab Station (IVLS) is a laboratory information management system created by IDEXX. Catalyst CRP Diagnostic Guidelines. Access Catalyst One Chemistry Analyser manuals, quick reference guides, sample preparation posters and more. Catalyst One; ProCyte Dx; LaserCyte Dx; All analysers & SNAP tests; Services Services View all Services ... Troubleshooting SNAP Test Results. Save technician time with load-and-go efficiency. Combine with a CBC, electrolytes and tests such as total T4, when indicated. Call IDEXX Technical Services, 1300 44 33 99. Choose only the appropriate test for your patient and perform activated partial thromboplastin time (aPTT) and/or prothrombin time (PT) tests using fresh or citrated whole blood. On Jul 2, we issued an updated research report on IDEXX Laboratories, Inc. IDXX. Using the Catalyst CRP Test. Maintain continuity of care. Save as much as $176,256 over six years with Abaxis! Dimensions & weight. Resources. Catalyst SDMA Test and Total T4 Kit Quick Reference Guide. Enter the sample information on the IDEXX VetLab Station. Small size is a big advantage. 2. However, if you have problems with a SNAP test, read the information below for help, and then rerun the test. Order now Abaxis has intelligent Quality Control (iQC)* built into every rotor test, and does not have monthly or quarterly service costs. Catalyst One; Procyte Dx; LaserCyte Dx; All analysers & SNAP tests; Services Services View all Services ... Troubleshooting SNAP Test Results. Catalyst One - Quality Control Log Version 1.0 (10.13) Catalyst CRP Diagnostic Guidelines. Use albumin level to guide safe administration of anaesthesia. View Catalyst One Chemistry Analyser resources. A focused chemistry foundation; combine with a CBC, electrolytes and other tests. Using the Catalyst CRP Test. General Work Flows and Maintenance Snippets Safety materials. Benefit from a more complete diagnostic workup with the ProCyte Dx Haematology Analyser. Catalyst CRP White Paper. Learn more. Visit https://www.idexx.co.uk/en-gb/veterinary/support/documents-resources/catalyst-dx-resources/ 4. VetTest analyzer/VetLyte analyzer If your control results do not fall within the specified range for the lot of quality-control material: • Check the expiration dates of the control material and the VetTest chemistry slides. Using the Catalyst Total T 4 Test. You can load the slides in any order when running SDMA on the Catalyst One Chemistry Analyzer or with 18 or fewer slides on the Catalyst Dx Chemistry Analyzer. Manual will be automatically added to "My Manuals", Measuring Instruments Idexx Coag Dx Quick Reference Manual, Measuring Instruments Idexx SediVue Dx Operator's Manual, Measuring Instruments Idexx VETLAB UA Operator's Manual, Measuring Instruments Idexx SNAP Pro Operator's Manual, Measuring Instruments Idexx VetTest Operator's Manual, Measuring Instruments Idexx SNAPshot Dx Operator's Manual, Measuring Instruments Idexx VetStat Quick Start Manual, Measuring Instruments Idexx SediVue Dx User Manual, Page 6: International Symbol Descriptions, Page 12: Catalyst One Analyzer Consumables, Page 16: Viewing And Printing Test Results, Page 17: Outside Of Reportable Range Samples, Page 18: Modifying The Settings On The Analyzer, Page 20: Preparing Samples For Use On The Catalyst One Analyzer, Page 25: Quality Control Clips And Slides, Page 29: Cleaning The Outside Of The Analyzer And The Sample Drawer, Page 58: Idexx Technical Support Contact Information. Results in minutes. We use cookies to ensure that we give you the best experience on our website. Footer navigation. Total T4 can be added to any test panel, allowing for a comprehensive chemistry, electrolyte and total T4 profile in one run with a single patient sample in approximately 15 minutes. Preparing Samples For Use on IDEXX Catalyst* Chemistry Analyzers poster. For information or to order. Dispense the sample into a whole blood separator and swirl. By connecting the Catalyst Dx analyzer to the IDEXX VetLab Station, you can: Choose the tests you want … Easy workflow. Load the sample and CLIPs or slides into the analyser. The company’s robust worldwide commercial capabilities and best-in-class products, including the next-generation chemistry analyzer, Catalyst One, are key growth drivers for the days to come. For the quickest time to results on the Catalyst One and Catalyst Dx chemistry analyzers, the recommended load order is Lyte 4 CLIP, chemistry CLIP (e.g., Chem 17, Chem 10), SDMA, total T 4 , with additional slides on top. Accurately measure your patients’ phenobarbital levels in minutes, for monitoring and timely adjustments during patient visits. Same-day pre- and postprandial results make patient management seamless. IDEXX Learning Center (U.S.) The IDEXX VetLab Station Certificate Course. Phone: 00800 727 43399 | 0031-23-55-87193 (direct) Email your customer support request. (300 µL is the recommended sample volume when running a Chem 17 CLIP and electrolytes.) Data on file at IDEXX Laboratories, Inc., Westbrook, Maine, United States. Learn about the Catalyst … No Color or Poor Color Development . Learn more. The stock carries a Zacks Rank #3 (Hold), at present. Total T 4 can be added to any test panel, allowing for a comprehensive chemistry, electrolyte and total T 4 profile in one run with a single patient sample in approximately 15 minutes.. Exact time to results may vary. IDEXX SNAP tests are very reliable. Tap Quality Control. Footer navigation. General Work Flows and Maintenance Safety materials. Easily recheck abnormal results, monitor patients and create custom panels with single slides. IDEXX (Material) Safety Data Sheets ([M]SDS) Sitemap. No, the Catalyst* Total T 4 Test contains a single slide and a reagent (conjugate, wash, and substrate). IDEXX, on the other hand, charges monthly chemistry Quality Control fees and monthly and quarterly Service Agreement fees. Sample Preparation Poster. IDEXX SmartService Solutions is an analyzer monitoring service that's always on. IDEXX Learning Center. Verify the accuracy of test results simply and conveniently, following the analyser’s monthly cleaning. Total T 4 Easily screen, diagnose and manage thyroid disease during the patient visit. 1. Quick Reference Guide. Catalyst One Chemistry Analyser Unprecedented clinical insight in one sample run during the patient visit In one run with one sample, get chemistry and electrolyte results in only 8 minutes, total T 4 in as little as 15 minutes. 2 Initiate the run on the IDEXX VetLab Station.